GS-C25 Angle Globe Valve - CNLD Valves

Gs-c25-angle-globe-valve


HOME > GS-C25-ANGLE-GLOBE-VALVE
GS-C25 Angle Globe Valve
DIN Angle Globe Valves are manufactured to the latest edition of EN 13709 and tested to EN12266-1.
 Share:

Applicable Standards:

Design EN 13709
Face to face EN 558-1
End Flanges EN 1092-1
Butt Welding ends EN 12627
Inspection and test EN 12266-1

Material: GS-C25
Size Range: DN15~DN400
Pressure Rating: PN16, PN25, PN40
Temperature Range: -50°C~650°C

Design Description:

-Straight pattern
– Outside Screw and York
– Bolted Bonnet
– Seat in stellite or 13%Cr
– Available with gear operator
– Flange Ends
– Butt-welding Ends

Structure Globe
Valve Material cast steel, stainless steel, special alloy, CI, DI etc
Valve Test 100% quantity tested before delivery
Valve Guarantee 18 months after shipments and 12 months after installed
Valve Structure Globe Valve
Valve Delivery 15 – 30 days
Valve Color Customer request
Valve Packing Plywood Case for Globe Valve
MOQ 1 Set
Valve Certificate API6D/CE/ISO9001/ISO14001
Place of Origin Zhejiang, China (Mainland)
Delivery Detail: Shipped in 15-30 days after payment
Payment Terms L/C,D/A,D/P,T/T, Western Union

 

Application & Function:

DIN Globe Check Valve structure is similar to globe valve, but the connection of stem and disc are not fixed. The globe check valve could run globe valve fuction when the stem drops and compresses the disc on the seat, while when the stem rises up, it could work as a check valve. When we need to install both globe valve and check valve on the pipe at the same time, or with limited installation area(e.g.ships),the globe check valve would be the best choice as it could save installation cost as well as space.

Globe Valve is used for throttling flow control. Shut off is accomplished by moving the disc against the flow stream rather than across it as in the case with a gate valve. The flow pattern through a globe valve involves changes in direction, resulting in greater resistance to flow, causing high pressure drop. The globe valve is an excellent valve to use for on-off service, but is highly suited for frequent cycling and control of fluids anywhere in amount or volume between the open and closed positions.

The Globe Check valve must be installed in the proper relation to the media flow as indicated by the flow direction arrow marked on the valve body. This valve is considered uni-directional and must be installed with the pressure side or inlet under the seat.

Accessories:
Gear operators, actuators, locking devices, chain wheels and So on, extended stems and bonnets for cryogenic service and many others are available to meet the customer’s requirements.

 

Contact Us
GET A QUOTE
We are a member of the ODK Valve Group, and we prioritize product quality and customer satisfaction. CNLD valves look forward to establishing new customer relationships by providing high-quality valves and working closely together.
Contact us
Privacy Policy | Sitemaps
Copyright © Zhejiang Led Valve Co. LTD, All Rights Reserved